Skip to content

Hardware Organized by Material Type

Liquids (Yield Stress < 100 Pa)

Air-Displacement Pipettes

Principle: Movable piston creates air gap above liquid; changes in air volume precisely push/pull liquid.

Accuracy: ±1–2% (excellent)
Speed: 30 sec per 10 mL
Cost: \(200–\)2000 per unit

Vendors: Eppendorf, Rainin, Gilson, Hamilton

Suitable materials: Water, solvents, dilute solutions (< 50 cP)

Limitations: Fail at viscosity > 100 cP; cannot handle yield-stress materials


Syringe Pumps

Principle: Motor drives syringe plunger at controlled speed; linear displacement → precise volume flow.

Accuracy: ±2–5%
Speed: 5–30 sec per 10 mL (depends on speed setting)
Cost: \(1k–\)10k per pump

Vendors: New Era, Infuse/Withdraw, Aladdin

Suitable materials: Low- to medium-viscosity liquids, some semi-solids

Advantages: Versatile, works on bench top, good for research


Peristaltic Pumps

Principle: Rotating rollers squeeze flexible tubing; material never touches pump.

Accuracy: ±5–10% (depends on tubing wear)
Speed: Tunable, 1–1000 mL/min
Cost: \(500–\)5k

Vendors: Watson-Marlow, Cole-Parmer, Gilson

Suitable materials: Any liquid (food-grade, sterile, corrosive); semi-solids at low rates

Advantages: No contact, aseptic, continuous flow


Acoustic Droplet Ejection (ADE)

Principle: Focused acoustic transducer creates pressure pulse; ejects nano-droplets from well plate.

Accuracy: ±15% (droplet-scale, high relative error)
Speed: Milliseconds per droplet
Cost: \(50k–\)200k (equipment)

Vendors: Echo (Beckman Coulter), Labcyte

Suitable materials: Aqueous solutions, low-viscosity liquids

Advantages: Contactless; useful for fragile reagents (proteins, cells)

Limitations: Expensive; droplet size ~50 nL; not for viscous liquids


Semi-Solids (Yield Stress 100 Pa – 100 kPa)

Screw Extrusion (Stepper Motor)

Principle: Stepper motor drives rotating screw; screw flutes push material out.

Accuracy: ±2–5% (depends on material uniformity)
Speed: 10–60 sec per mL
Cost: \(3k–\)15k

Vendors: Asymptotic, Ultimaker (3D printer heads)

Suitable materials: Bio-inks, pastes, gels, highly viscous liquids

Advantages: Decouples flow from applied pressure; good control


Air-Pressure Syringes

Principle: Compressed air pushes on syringe plunger; material is extruded through nozzle.

Accuracy: ±5–15% (sensitive to pressure fluctuations)
Speed: 5–30 sec per mL
Cost: \(2k–\)8k (syringe + regulator)

Vendors: EFD (Eaton), Asymptotic, Nordson

Suitable materials: Pastes, gels, gentle on cells (low shear)

Advantages: Gentle, no motor vibration; good for bio-inks

Limitations: Pressure fluctuation → volume variation; requires fast feedback for ±1%


Progressive Cavity Pumps

Principle: Single rotating screw in elliptical cavity; creates expanding cells that push fluid.

Accuracy: ±1–3%
Speed: Tunable, 10–1000 mL/min
Cost: \(5k–\)20k

Vendors: Mono (Halliburton), Netzsch

Suitable materials: High-viscosity, yield-stress, shear-sensitive materials

Advantages: Gentle pumping action; excellent for viscous polymers, cells


Powders (Yield Stress 10 kPa – 1 MPa)

Auger / Screw Feeders

Principle: Rotating screw conveys powder from hopper to exit; volume per revolution ≈ constant.

Accuracy: ±2–8% (depends on flowability)
Speed: 10–30 sec per gram
Cost: \(2k–\)10k

Vendors: Maersk, Acrison, Schenck Process

Suitable materials: Free-flowing to moderately cohesive powders

Limitations: Fails with bridging powders; accuracy limited by slip

Improvement: Variable-pitch screws, vacuum assist


Vibratory Hoppers

Principle: Vibrating bin loosens powder; gravity feeds through metered orifice.

Accuracy: ±5–15% (poor for cohesive materials)
Speed: Fast, 2–10 sec per gram
Cost: \(1k–\)5k

Vendors: Vibra, Carr Lane

Suitable materials: Free-flowing powders only

Limitations: Electrostatic buildup; poor accuracy; doesn't work for sticky powders


Vacuum-Assisted Dosing

Principle: Suction creates vacuum through metered orifice; powder is pulled out by air flow.

Accuracy: ±1–3%
Speed: 10–20 sec per gram
Cost: \(5k–\)15k

Vendors: GEA, Schenck Process, Coptis

Suitable materials: Cohesive and fine powders; even electrostatic materials

Advantages: Works with difficult powders; good accuracy


Fluidized-Bed Dispensers

Principle: Air flows up through porous membrane; powder floats weightless; exit through calibrated nozzle.

Accuracy: ±0.5–2% (excellent)
Speed: 10–30 sec per gram
Cost: \(10k–\)50k

Vendors: Coptis, Netzsch, Schenck Process

Suitable materials: All powders (even bridging, cohesive, electrostatic)

Advantages: Highest accuracy; works with all powder types

Limitations: High cost; requires compressed air supply


Gravimetric Feedback Systems

Principle: Real-time weighing on collection vessel; adjusts feeder speed to match target.

Accuracy: ±0.5–1% (depends on scale precision)
Speed: 20–60 sec per dose (includes feedback cycles)
Cost: \(8k–\)30k (feeder + scale + controller)

Vendors: Mettler-Toledo, Schenck Process, Acrison

Suitable materials: Any powder

Control strategy: Iterative Optimization (Strategy 2) or Real-Time Correction (Strategy 3)


Solids (Yield Stress > 1 MPa)

6-DOF Collaborative Robots

Principle: Motorized joints, each with encoders and torque sensors; compute target positions via kinematics.

Accuracy: ±0.03–0.05 mm (excellent positional repeatability)
Speed: Cycle time 5–30 sec (depends on task)
Cost: \(30k–\)80k per arm

Vendors: Universal Robots (UR3e, UR5), KUKA, Franka Emika, ABB

Suitable for: Object pick-and-place, assembly, inspection

Control strategies: Tactile Retrieval (Strategy 7), Real-Time Correction (Strategy 3)


Grippers

Parallel Gripper

  • Cost: \(1k–\)3k
  • Grip force: 100–1000 N
  • Suitable: Rigid objects, boxes, rigid parts
  • Limitations: Cannot adapt to soft or irregular shapes

Vacuum Gripper

  • Cost: \(500–\)2k (suction cup only)
  • Lifting capacity: 1–50 kg (depends on cup area, vacuum pump)
  • Suitable: Flat, smooth, non-porous objects
  • Limitations: Won't work on porous or deformable materials

Soft Gripper

  • Cost: \(2k–\)10k
  • Grip force: 1–10 N (gentle)
  • Suitable: Delicate objects (tissue, fruit, fragile electronics)
  • Limitations: Lower speed; may slip on smooth hard objects

Electroadhesion Gripper

  • Cost: \(3k–\)10k
  • Lifting capacity: 10–500 g (depends on voltage, material)
  • Suitable: Any material (uses electrostatic force)
  • Advantages: Non-contact; works on glass, foil, ceramics
  • Limitations: Requires conductive gripper pad and target

Pick-and-Place Systems (Gantry / SCARA)

Principle: Fast XY(Z) motion; specialized for high-speed discrete part handling.

Accuracy: ±0.5–2 mm
Speed: 1–3 sec per pick (very fast)
Cost: \(15k–\)80k

Vendors: ABB, Stäubli, Fanuc, Yaskawa

Suitable for: Tablets, pellets, small assemblies (food, pharma, electronics)

Advantages: Faster than 6-DOF robots for planar tasks


Comparison Table: Key Commercial Systems

System Yield Stress Range Accuracy Speed Cost Strategy
Air-displacement pipette 1–50 Pa ±1–2% 30 sec/10mL $1k Characterize
Syringe pump 10–1000 Pa ±2–5% 10 sec/mL $5k Iterate
Air-pressure syringe 100–10k Pa ±5–15% 10 sec/mL $5k Real-time correct
Screw extrusion 500–50k Pa ±2–5% 20 sec/mL $8k Iterate/Predict
Auger feeder 10k–1M Pa ±2–8% 10 sec/g $5k Characterize
Vacuum dispenser 100k–1M Pa ±1–3% 15 sec/g $10k Iterate
Fluidized-bed 100k–10M Pa ±0.5–2% 20 sec/g $30k Iterate/Feedback
Collaborative robot > 1M Pa ±0.03 mm 5–30 sec $50k Tactile

Further Exploration

For each material type, see the Material Properties page for characterization protocols, and Recurring Strategies for recommended control approaches.

For cost vs. accuracy trade-offs, see By Yield Stress & Cost.